Advertisement
Open to Debate – Referee| Volume 44, P76-77, October 2022

Is the Choice Between Clips and No Clips or Cautery and No Cautery Still a Dilemma in Robot-assisted Radical Prostatectomy?

  • Walter Artibani
    Correspondence
    Corresponding author. Department of Urology, Abano Terme Hospital, Piazza Cristoforo Colombo, 1, 35031 Abano Terme, Italy.
    Affiliations
    Department of Urology, Policlinico Abano Terme, Abano Terme, Italy

    University of Verona, Verona, Italy
    Search for articles by this author
  • Giovanni Cacciamani
    Affiliations
    USC Institute of Urology and Catherine and Joseph Aresty Department of Urology, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
    Search for articles by this author
Open AccessPublished:August 30, 2022DOI:https://doi.org/10.1016/j.euros.2022.08.010
      In the two papers in this Open to Debate series, de la Taille [
      • de la Taille A.
      Nerve-sparing techniques during robot-assisted radical prostatectomy: clips or low-energy bipolar coagulation? Low energy.
      ] defends the position that a clipless technique during robot-assisted radical prostatectomy—using low-energy bipolar coagulation of short duration—is feasible and reproducible, yielding similar outcomes (continence and potency recovery) to those achieved with the “standard” approach (clips and no energy) that is advocated by Zhu et al. [
      • Zhu A
      • Basourakos SP
      • Hu JC
      Nerve-sparing techniques during robot-assisted radical prostatectomy: clips.
      ].
      Theoretically, damage to the unmyelinated nervous fibers of the neurovascular bundles can be direct (mechanical or thermal) or indirect (traction, inflammation, fibrosis). Clips avoid thermal damage, but their precise positioning depends on the table assistant. Clip compression of tissue extends to at least 2 mm, and clips may provoke a local reaction, such as moderate mucosal inflammation with granulation tissue [
      • Delibegović S.
      • Iljazović E.
      • Katica M.
      • Koluh A.
      Tissue reaction to absorbable endoloop, nonabsorbable titanium staples, and polymer Hem-o-Lok clip after laparoscopic appendectomy.
      ] and consequent formation of adhesions [
      • Bajric A.
      • Delibegovic S.
      • Cickusic E.
      • Katica M.
      • Sivic M.
      Tissue reaction and the formation of adhesion after the use of DS clip in laparoscopic appendectomy.
      ], and they can migrate at the level of the bladder neck and vesicourethral anastomosis [
      • Cormio L.
      • Massenio P.
      • Lucarelli G.
      • et al.
      Hem-o-Lok clip: a neglected cause of severe bladder neck contracture and consequent urinary incontinence after robot-assisted laparoscopic radical prostatectomy.
      ]. Successful use of energy (monopolar or bipolar cautery, ultrasonic shears) is related not only to proper positioning but also to the duration, power, and type of energy delivered. Pinpoint low energy (≤30 W) of short duration (<1 s), preferably bipolar, is the commonly agreed indication.
      The maxim to “avoid energy and use clips”, the so-called “standard” technique, is mainly based on one paper from Johns Hopkins Medical Institutions [
      • Ong A.M.
      • Su L.M.
      • Varkarakis I.
      • et al.
      Nerve sparing radical prostatectomy: effects of hemostatic energy sources on the recovery of cavernous nerve function in a canine model.
      ]. The paper refers to an elegant and well-designed canine study in which 12 dogs were divided into four groups (three dogs per group) undergoing unilateral nerve-sparing surgery using ligatures, monopolar cautery, bipolar cautery, or ultrasonic shears. Postoperative evaluation was based on measurement of intracavernous pressure after electrical stimulation of the cavernous nerves in the untouched bundle and the bundle operated on. Both immediately after surgery and at 2 wk, there was a clear advantage with ligatures in comparison to the use of thermal energy. How can this result be transferred to real life, in which many other variables may impact the outcome of interest, such as age, local hematoma, inflammation, fibrosis, neural regeneration over time, motivation, rehabilitation, surgeon expertise, and follow-up time, just to mention a few?
      What is the scientific basis for the use of different energies? Hefermehl et al. [
      • Hefermehl L.J.
      • Largo R.A.
      • Hermanns T.
      • Poyet C.
      • Sulser T.
      • Eberli D.
      Lateral temperature spread of monopolar, bipolar and ultrasonic instruments for robot-assisted laparoscopic surgery.
      ] analyzed the impact of different energies on a model involving strips of fresh bovine muscle fascia, and the results give clear messages regarding the depth of thermal damage in various settings. Again, how can these data be transferred to real life? The neurovascular bundle structure is very far from the fascia, and many factors are not taken into consideration (tissue impedance, local temperature, CO2 atmosphere).Of note, some studies have examined the efficacy of clipping in thoracic sympathectomy in animals, highlighting the fact that clips can provoke neural damage [
      • Salcı H.
      • Acar H.
      • Taşkapılıoğlu M.
      • Melek H.
      • Bayram A.S.
      Electrophysiological evaluation of efficacy of clipping in thoracic sympathectomy: an experimental cadaveric study.
      ] involving fibrinous material and polymorphonuclear leukocyte infiltration with fat necrosis [
      • Candas F.
      • Gorur R.
      • Haholu A.
      • et al.
      The effects of clipping on thoracic sympathetic nerve in rabbits: early and late histopathological findings.
      ] that prevents impulse conduction.
      Surgical “standards” are often based on concepts founded on traditions, hypotheses, and beliefs with a debatable scientific basis. Several cognitive biases also play a role, including framing, representative, confirmation, and anchoring biases. This intrinsic weakness of surgical knowledge could be explained by the fact that in any surgical procedure there are so many interconnected variables—surgical and nonsurgical—that it is challenging to extrapolate a single factor.
      In our personal practice, we have been and are advocates of pinpoint low-energy monopolar cautery of short duration [
      • Artibani W.
      • Cacciamani G.
      The apical dissection.
      ]. A careful review of the literature regarding the experiences of others reveals starting points on one hand of the difficult treatment of some cases in which Hem-o-Lok clips can migrate at the level of the vesicourethral anastomosis [
      • Cormio L.
      • Massenio P.
      • Lucarelli G.
      • et al.
      Hem-o-Lok clip: a neglected cause of severe bladder neck contracture and consequent urinary incontinence after robot-assisted laparoscopic radical prostatectomy.
      ], and on the other the observation of a young patient regaining erectile function in 2–3 wk despite the use of cautery. Clearly, this case is anecdotal and an enlightening example of the importance of evidence-based practice. However, emerging clinical data show similar outcomes with different techniques, as cited by de la Taille [
      • de la Taille A.
      Nerve-sparing techniques during robot-assisted radical prostatectomy: clips or low-energy bipolar coagulation? Low energy.
      ] and Zhu et al. [
      • Zhu A
      • Basourakos SP
      • Hu JC
      Nerve-sparing techniques during robot-assisted radical prostatectomy: clips.
      ].
      The ideal strategy would be to design prospective randomized or comparative studies with the main objective of showing whether energy use is detrimental in comparison to thermal clip procedures. Unfortunately, there are an overwhelming number of confounding variables. Such studies are challenging to design and conclusions can be biased. A more feasible option would be studies in animal models using modern robotic techniques with or without clips, and the study by Hefermehl et al. [
      • Hefermehl L.J.
      • Largo R.A.
      • Hermanns T.
      • Poyet C.
      • Sulser T.
      • Eberli D.
      Lateral temperature spread of monopolar, bipolar and ultrasonic instruments for robot-assisted laparoscopic surgery.
      ] paves the way to such an approach.
      In conclusion, the debate is open and no verdict can be delivered. Meanwhile, practice should be based on continuous scrupulous and honest evaluation of personal outcomes.
      Conflicts of interest: The authors have nothing to disclose.

      References

        • de la Taille A.
        Nerve-sparing techniques during robot-assisted radical prostatectomy: clips or low-energy bipolar coagulation? Low energy.
        Eur Urol Open Sci. 2022; : 44https://doi.org/10.1016/j.euros.2022.06.011
        • Zhu A
        • Basourakos SP
        • Hu JC
        Nerve-sparing techniques during robot-assisted radical prostatectomy: clips.
        Eur Urol Open Sci. 2022; : 44https://doi.org/10.1016/j.euros.2022.06.012
        • Delibegović S.
        • Iljazović E.
        • Katica M.
        • Koluh A.
        Tissue reaction to absorbable endoloop, nonabsorbable titanium staples, and polymer Hem-o-Lok clip after laparoscopic appendectomy.
        J Soc Laporosc Robot Surg. 2011; 15: 70-76
        • Bajric A.
        • Delibegovic S.
        • Cickusic E.
        • Katica M.
        • Sivic M.
        Tissue reaction and the formation of adhesion after the use of DS clip in laparoscopic appendectomy.
        J Soc Laporosc Robot Surg. 2021; 25e2021.00063
        • Cormio L.
        • Massenio P.
        • Lucarelli G.
        • et al.
        Hem-o-Lok clip: a neglected cause of severe bladder neck contracture and consequent urinary incontinence after robot-assisted laparoscopic radical prostatectomy.
        BMC Urol. 2014; 14: 21
        • Ong A.M.
        • Su L.M.
        • Varkarakis I.
        • et al.
        Nerve sparing radical prostatectomy: effects of hemostatic energy sources on the recovery of cavernous nerve function in a canine model.
        J Urol. 2004; 172: 1318-1322
        • Hefermehl L.J.
        • Largo R.A.
        • Hermanns T.
        • Poyet C.
        • Sulser T.
        • Eberli D.
        Lateral temperature spread of monopolar, bipolar and ultrasonic instruments for robot-assisted laparoscopic surgery.
        BJU Int. 2014; 114: 245-252
        • Salcı H.
        • Acar H.
        • Taşkapılıoğlu M.
        • Melek H.
        • Bayram A.S.
        Electrophysiological evaluation of efficacy of clipping in thoracic sympathectomy: an experimental cadaveric study.
        Turk Gogus Kalp Damar Cerrahisi Derg. 2020; 28: 669-673
        • Candas F.
        • Gorur R.
        • Haholu A.
        • et al.
        The effects of clipping on thoracic sympathetic nerve in rabbits: early and late histopathological findings.
        Thorac Cardiovasc Surg. 2012; 60: 280-284
        • Artibani W.
        • Cacciamani G.
        The apical dissection.
        in: John H. Wiklund P. Robotic urology. Springer International Publishing, Cham, Switzerland2018: 355-361

      Linked Article